COMPUTANK

Computerized Tank Monitoring System
For Fuel, Oil, and Potable Water Tanks

Standard Hook Up

standard hook up
Wiring:  It is recommended that number 16 AWG wire and crimp eyelet
type terminals with insulated shanks be used to wire sending units to
avoid the possibility of shorting the terminals.  Secure all wire terminations
with nuts and lock washers.

Put a generous coating of sealant over the wire terminals and the adjustment
screws. 
silb Connect a wire from the POS terminal of each sending unit and CompuTank
power plug to the 12 volt (24V or 32V if specified) electrical system at some
point after the ignition switch and fuse block.
silb Connect a wire from the NEG terminal of each sending unit to its respective
terminal on the sending unit connector plug and from the negative terminal
on the CompuTank power plug to the battery ground bus.
silb Connect a wire from the SEND terminal of each sending unit to its respective
terminal on the CompuTank sending unit connector plug.